Spectrometers & sensors
Oxygen Sensors
Fluorescence Quenching
This is the ultimate technology for measuring oxygen. We trap a fluorescent compound in an oxygen permeable, optically clear sol gel matrix. The fluoresence of this compound is excited by a blue LED. Molecular oxygen collides with the excited state of the fluorophore and releases the enrgy non-radiatively. This queching effect is measured by phase fluorimetry, and is use to determine pO2 in the sensor
Sensor Type Material Length Pressure Description Price FOX-R 1/16” SS 152mm 300 psi General lab $577 FOS-R 1/16” SS 152mm 300 psi $577 HIOX-R 1/16” SS 152mm 300 psi $866 FOX-OR125 1/8” SS 63.5mm 300 psi For 1/8” electrode repl $692 FOS-OR125 1/8” SS 63.5mm 300 psi $692 HIOX-OR125 1/8” SS 63.5mm 300 psi $1039 FOX-OR125-G 1/8” SS 63.5mm 300 psi With o’ ring groove $692 FOS-OR125-G 1/8” SS 63.5mm 300 psi $692 HIOX-OR125-G 1/8” SS 63.5mm 300 psi $1039 FOX-T1000 ¼” SS 177.8mm 3000 psi Online, process $1154 FOS-T1000 ¼” SS 177.8mm 3000 psi $1154 HIOX-T1000 ¼” SS 177.8mm 3000 psi $1732 FOX-T1000-RTD ¼” SS 177.8mm 3000 psi Online process with embedded RTD $1732 FOS-T1000-RTD ¼” SS 177.8mm 3000 psi $2309 HIOX-T1000-RTD ¼” SS 177.8mm 3000 psi $1732 FOX-AL300 500um Al 1m 300 psi Flexible Al jacketed 300um fiber $577 FOS-AL300 500um Al 1m 300 psi $577 HIOX-AL300 500um Al 1m 300 psi $577 FOX-PI600 710um PI 2m 300 psi Flexible polyimide fiber with black silicone overcoat $577 FOS-PI600 710um PI 2m 300 psi $577 FOX-18G 18 gauge 1.27mm 90mm tip 300 psi 18G Needle tip with side hole for sensor $692 FOS-18G 18 gauge 1.27mm 90mm tip 300 psi $692 HIOX-18G 18 gauge 1.27mm 90mm tip 300 psi $1039 FOX-21G 21 gauge 0.8mm 90mm tip 300 psi 21G Needle with side hole for sensor $692 FOS-21G 21 gauge 0.8mm 90mm tip 300 psi $692 HIOX-21G 21 gauge 0.8mm 90mm tip 300 psi $1039 
Fiber Optic Sensors -- Small enough to fit into needles, rugged enough to fit into industrial style sensors. The sensor material is coated on the tip of the optical fiber. There are dozens of styles and options. Do you need something we don't show? We make custom work routine. Call us to tell us about your requirements.
Remote Detection -- That's right! We can sense the fluorescent decay time from a distance. Our Red Eye patches can be put on the inside of package, vial, respirometer, you name it. Point the fiber optic probe at the patch and get a fast accurate answer.
Three Formulations
Chemical |
FOXY & FOSPOR |
HIOXY |
Acetone |
No |
No |
Acetonitrile |
No |
unknown |
Acids |
Yes |
Yes |
Acrylonitrile |
No |
unknown |
Alcohols <50% |
Yes |
Yes |
Alcohols > 50% |
No |
Yes |
Ammonia |
Yes |
unknown |
Benzene |
No |
Yes |
Bleach (20%r) |
Yes |
unknown |
Cyclohexane |
No |
Yes |
Diesel Fuel |
No |
Yes |
Ethanol |