Description: |
Rectangular Spectrophotometer Cells |
|
Physical Configuration: |
Standard window and wall thickness (1.25mm) see other dimensions on charts below |
|
Primary use: |
Absorbance measurement |
|
Clear windows: |
Two |
|
Instrument: |
Can be used with spectrophotometers and colorimeters |
|
Pathlengths available: |
1, 2, 5, 10, 20, 40, 50, 100mm |
|
Most commonly used path length: |
10mm |
|
Cell top: |
Open top, supplied with a non-sealing PTFE cover |
|
|
|
|
Window material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
||||||||
|
|
Path |
Exterior |
Interior |
Nominal |
Number |
|||
|
Catalog |
Length |
Width |
Length |
Height |
Width |
Length |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
1/Q/1 |
1 |
12.5 |
3.5 |
45 |
10 |
1 |
0.400 |
2 |
|
1/Q/2 |
2 |
12.5 |
4.5 |
45 |
10 |
2 |
0.700 |
2 |
|
1/Q/5 |
5 |
12.5 |
7.5 |
45 |
10 |
5 |
1.700 |
2 |
|
1/Q/10 |
10 |
12.5 |
12.5 |
45 |
10 |
10 |
3.500 |
2 |
|
1/Q/20 |
20 |
12.5 |
22.5 |
45 |
10 |
20 |
7.000 |
2 |
|
1/Q/40 |
40 |
12.5 |
42.5 |
45 |
10 |
40 |
14.000 |
2 |
|
1/Q/50 |
50 |
12.5 |
52.5 |
45 |
10 |
50 |
15.000 |
2 |
|
1/Q/100 |
100 |
12.5 |
102.5 |
45 |
10 |
100 |
35.000 |
2 |

|
Description: |
Rectangular Spectrophotometer Cells |
|
Physical Configuration: |
Standard window and wall thickness (1.25mm) see other dimensions on charts below |
|
Primary use: |
Absorbtion measurement in useable range (see charts below) |
|
Clear windows: |
Two |
|
Instrument: |
Can be used with spectrophotometers and colorimeters |
|
Pathlengths available: |
1, 2, 5, 10, 20, 40, 50, 100mm |
|
Most commonly used path length: |
10mm |
|
Cell top: |
PTFE stopper in "ground type" joint. Liquid tight for up to 12 hours |
|
Window material Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm. |
||||||||
|
Starna |
Path |
Exterior |
Interior |
Nominal |
Number |
|||
|
Catalog |
Length |
Width |
Length |
Height |
Width |
Length |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
21/Q/1 |
1 |
12.5 |
3.5 |
55 |
10 |
1 |
0.400 |
2 |
|
21/Q/2 |
2 |
12.5 |
4.5 |
55 |
10 |
2 |
0.700 |
2 |
|
21/Q/5 |
5 |
12.5 |
7.5 |
48 |
10 |
5 |
1.700 |
2 |
|
21/Q/10 |
10 |
12.5 |
12.5 |
48 |
10 |
10 |
3.500 |
2 |
|
21/Q/20 |
20 |
12.5 |
22.5 |
48 |
10 |
20 |
7.000 |
2 |
|
21/Q/40 |
40 |
12.5 |
42.5 |
48 |
10 |
40 |
14.000 |
2 |
|
21/Q/50 |
50 |
12.5 |
52.5 |
48 |
10 |
50 |
15.000 |
2 |
|
21/Q/100 |
100 |
12.5 |
102.5 |
48 |
10 |
100 |
35.000 |
2 |

|
Description:
|
Semi-Micro
Spectrophotometer Cells |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 4mm wide |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Can
be used with spectrophotometers and colorimeters |
|
Pathlengths
available: |
5,
10, 20, 40, 50, 100mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
Open
top, supplied with a non-sealing PTFE cover |
|
Usage
note: |
Thick
base (9/9) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
9/Q/5 |
5 |
12.5 |
7.5 |
45 |
4 |
5 |
2.5 |
0.700 |
2 |
|
9/Q/10 |
10 |
12.5 |
12.5 |
45 |
4 |
10 |
2.5 |
1.400 |
2 |
|
9/9/Q/10 |
10 |
12.5 |
12.5 |
45 |
4 |
10 |
9 |
1.160 |
2 |
|
9/Q/20 |
20 |
12.5 |
22.5 |
45 |
4 |
20 |
2.5 |
2.800 |
2 |
|
9/Q/40 |
40 |
12.5 |
42.5 |
45 |
4 |
40 |
2.5 |
5.600 |
2 |
|
9/Q/50 |
50 |
12.5 |
52.5 |
45 |
4 |
50 |
2.5 |
7.000 |
2 |
|
9/Q/100 |
100 |
12.5 |
102.5 |
45 |
4 |
100 |
2.5 |
14.000 |
2 |
|
|
|
|
|
|
|
|
|
|
|

|
Description:
|
Semi-Micro
Spectrophotometer Cells |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 4mm wide, black walls
parallel to the light beam |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Can
be used with spectrophotometers and colorimeters |
|
Pathlengths
available: |
5,
10, 20, 40, 50mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
Open
top, supplied with a non-sealing PTFE cover |
|
Usage
note: |
Thick
base (9/9B) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
9B/Q/5 |
5 |
12.5 |
7.5 |
45 |
4 |
5 |
2.5 |
0.700 |
2 |
|
9B/Q/10 |
10 |
12.5 |
12.5 |
45 |
4 |
10 |
2.5 |
1.400 |
2 |
|
9/9B/Q/10 |
10 |
12.5 |
12.5 |
45 |
4 |
10 |
9 |
1.160 |
2 |
|
9B/Q/20 |
20 |
12.5 |
22.5 |
45 |
4 |
20 |
2.5 |
2.800 |
2 |
|
9B/Q/40 |
40 |
12.5 |
42.5 |
45 |
4 |
40 |
2.5 |
5.600 |
2 |
|
9B/Q/50 |
50 |
12.5 |
52.5 |
45 |
4 |
50 |
2.5 |
7.000 |
2 |

|
Description:
|
Semi-Micro
Spectrophotometer Cells, with stopper |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 4mm wide |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Can
be used with spectrophotometers and colorimeters |
|
Pathlengths
available: |
5,
10, 20, 40, 50mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
PTFE
stopper in "ground type" joint. Liquid tight for up to 12 hours |
|
Usage
note: |
Thick
base (29/9) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
29/Q/5 |
5 |
12.5 |
7.5 |
48 |
4 |
5 |
2.5 |
0.700 |
2 |
|
29/Q/10 |
10 |
12.5 |
12.5 |
48 |
4 |
10 |
2.5 |
1.400 |
2 |
|
29/9/Q/10 |
10 |
12.5 |
12.5 |
48 |
4 |
10 |
9 |
1.160 |
2 |
|
29/Q/20 |
20 |
12.5 |
22.5 |
48 |
4 |
20 |
2.5 |
2.800 |
2 |
|
29/Q/40 |
40 |
12.5 |
42.5 |
48 |
4 |
40 |
2.5 |
5.600 |
2 |
|
29/Q/50 |
50 |
12.5 |
52.5 |
48 |
4 |
50 |
2.5 |
7.000 |
2 |

|
Description: |
Semi-Micro Spectrophotometer Cells, with stopper |
|
Physical Configuration: |
Walls parallel to the light path thickened, sample chamber is 4mm wide. Walls parallel to the light beam are black masked for improved sensitivity. |
|
Primary use: |
Absorbtion measurement using reduced volume |
|
Clear windows: |
Two |
|
Instrument: |
Can be used with spectrophotometers and colorimeters |
|
Pathlengths available: |
5, 10, 20, 40, 50mm |
|
Most commonly used path length: |
10mm |
|
Cell top: |
PTFE stopper in "ground type" joint. Liquid tight for up to 12 hours |
|
Usage note: |
Thick base (29B/9) can not be used with instruments having a Z dimension of 8.5mm |
|
Window material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
29B/Q/5 |
5 |
12.5 |
7.5 |
48 |
4 |
5 |
2.5 |
0.700 |
2 |
|
29B/Q/10 |
10 |
12.5 |
12.5 |
48 |
4 |
10 |
2.5 |
1.400 |
2 |
|
29/9B/Q/10 |
10 |
12.5 |
12.5 |
48 |
4 |
10 |
9 |
1.160 |
2 |
|
29B/Q/20 |
20 |
12.5 |
22.5 |
48 |
4 |
20 |
2.5 |
2.800 |
2 |
|
29B/Q/40 |
40 |
12.5 |
42.5 |
48 |
4 |
40 |
2.5 |
5.600 |
2 |
|
29B/Q/50 |
50 |
12.5 |
52.5 |
48 |
4 |
50 |
2.5 |
7.000 |
2 |

|
Description:
|
Micro
Spectrophotometer Cells |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 2mm wide |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Designed
for use with spectrophotometers |
|
Pathlengths
available: |
5,
10, 20, 40, 50, 100mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
Open
top, supplied with a non-sealing PTFE cover |
|
Usage
note: |
Thick
base (18/9) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
Starna |
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
18/Q/5 |
5 |
12.5 |
7.5 |
45 |
2 |
5 |
2.5 |
0.350 |
2 |
|
18/Q/10 |
10 |
12.5 |
12.5 |
45 |
2 |
10 |
2.5 |
0.700 |
2 |
|
18/9/Q/10 |
10 |
12.5 |
12.5 |
45 |
2 |
10 |
9 |
0.580 |
2 |
|
18/Q/20 |
20 |
12.5 |
22.5 |
45 |
2 |
20 |
2.5 |
1.400 |
2 |
|
18/Q/40 |
40 |
12.5 |
42.5 |
45 |
2 |
40 |
2.5 |
2.800 |
2 |
|
18/Q/50 |
50 |
12.5 |
52.5 |
45 |
2 |
50 |
2.5 |
3.500 |
2 |
|
18/Q/100 |
100 |
12.5 |
102.5 |
45 |
2 |
100 |
2.5 |
7.000 |
2 |

|
Description:
|
Micro
Spectrophotometer Cells |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 2mm wide. Walls
parallel to the light beam are black. |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Designed
for use with spectrophotometers |
|
Pathlengths
available: |
5,
10, 20, 40, 50mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
Open
top, supplied with a non-sealing PTFE cover |
|
Usage
note: |
Thick
base (18/9B) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
18B/Q/5 |
5 |
12.5 |
7.5 |
45 |
2 |
5 |
2.5 |
0.350 |
2 |
|
18B/Q/10 |
10 |
12.5 |
12.5 |
45 |
2 |
10 |
2.5 |
0.700 |
2 |
|
18/9B/Q/10 |
10 |
12.5 |
12.5 |
45 |
2 |
10 |
9 |
0.580 |
2 |
|
18B/Q/20 |
20 |
12.5 |
22.5 |
45 |
2 |
20 |
2.5 |
1.400 |
2 |
|
18B/Q/40 |
40 |
12.5 |
42.5 |
45 |
2 |
40 |
2.5 |
2.800 |
2 |
|
18B/Q/50 |
50 |
12.5 |
52.5 |
45 |
2 |
50 |
2.5 |
3.500 |
2 |

|
Description:
|
Micro
Spectrophotometer Cells with stopper |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 2mm wide |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Designed
for use with spectrophotometers |
|
Pathlengths
available: |
5,
10, 20, 40, 50mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
PTFE
stopper in "ground type" joint. Liquid tight for up to 12 hours |
|
Usage
note: |
Thick
base (28/9) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
28/Q/5 |
5 |
12.5 |
7.5 |
48 |
2 |
5 |
2.5 |
0.350 |
2 |
|
28/Q/10 |
10 |
12.5 |
12.5 |
48 |
2 |
10 |
2.5 |
0.700 |
2 |
|
28/9/Q/10 |
10 |
12.5 |
12.5 |
48 |
2 |
10 |
9 |
0.580 |
2 |
|
28/Q/20 |
20 |
12.5 |
22.5 |
48 |
2 |
20 |
2.5 |
1.400 |
2 |
|
28/Q/40 |
40 |
12.5 |
42.5 |
48 |
2 |
40 |
2.5 |
2.800 |
2 |
|
28/Q/50 |
50 |
12.5 |
52.5 |
48 |
2 |
50 |
2.5 |
3.500 |
2 |

|
Description:
|
Micro
Spectrophotometer Cells with stopper, self masking |
|
Physical
Configuration: |
Walls
parallel to the light path thickened, sample chamber is 2mm wide. The walls
parallel to the light beam are black to improve sensitivity. |
|
Primary
use: |
Absorbtion
measurement using reduced volume |
|
Clear
windows: |
Two |
|
Instrument: |
Designed
for use with spectrophotometers |
|
Pathlengths
available: |
5,
10, 20, 40, 50mm |
|
Most
commonly used path length: |
10mm |
|
Cell
top: |
PTFE
stopper in "ground type" joint. Liquid tight for up to 12 hours |
|
Usage
note: |
Thick
base (28/9B) can not be used with instruments having a Z dimension of 8.5mm |
|
Window
material: Spectrosil® Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Interior |
Base |
Nominal |
Number |
|||
|
Catalogue |
Length |
W |
L |
H |
W |
L |
Thick |
Volume |
Polished |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ml |
Windows |
|
28B/Q/5 |
5 |
12.5 |
7.5 |
48 |
2 |
5 |
2.5 |
0.350 |
2 |
|
28B/Q/10 |
10 |
12.5 |
12.5 |
48 |
2 |
10 |
2.5 |
0.700 |
2 |
|
28/9B/Q/10 |
10 |
12.5 |
12.5 |
48 |
2 |
10 |
9 |
0.580 |
2 |
|
28B/Q/20 |
20 |
12.5 |
22.5 |
48 |
2 |
20 |
2.5 |
1.400 |
2 |
|
28B/Q/40 |
40 |
12.5 |
42.5 |
48 |
2 |
40 |
2.5 |
2.800 |
2 |
|
28B/Q/50 |
50 |
12.5 |
52.5 |
48 |
2 |
50 |
2.5 |
3.500 |
2 |

|
Description: |
Sub-Micro Spectrophotometer Cells |
|
Physical Configuration: |
Small sample chamber, 2mm wide, in fully masked standard exterior size cell |
|
Primary use: |
Absorbtion measurement using microliter volumes |
|
Clear windows: |
Two |
|
Instrument: |
Can be used with most spectrophotometers |
|
Pathlengths available: |
10mm |
|
Sample volumes: |
10, 40, 50, 100, 160 microliter |
|
Cell top: |
Open top, supplied with a PTFE (non-sealing) and polyethylene (liquid tight) cover |
|
Usage note: |
"Z" dimension is critical as the cell compartment must be correctly aligned in your instrument light beam. Check the chart below to make sure that you get a cell with the correct "Z" dimension for your instrument |
|
Usage note: |
When using aqueous samples, overfill by about 15% to raise the miniscus above the window aperture. |
|
Window material: Spectrosil Quartz or equivalent, useable range: 170 to 2700nm |
|||||||||
|
|
Path |
Exterior |
Window |
"Z" |
Geo |
Aq. |
|||
|
Catalog |
|
W |
L |
H |
W |
H |
|
Vol |
Vol |
|
Number |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
ul |
ul |
|
|
|
|
|
|
|
|
|
|
|
|
16.10-Q-10/Z8.5 |
10 |
12.5 |
12.5 |
45 |
1 |
1 |
8.5 |
10 |
15 |
|
16.10-Q-10/Z15 |
10 |
12.5 |
12.5 |
45 |
1 |
1 |
15 |
10 |
15 |
|
16.10-Q-10/Z20 |
10 |
12.5 |
12.5 |
45 |
1 |
1 |
20 |
10 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
16.40-Q-10/8.5 |
10 |
12.5 |
12.5 |
45 |
2 |
2 |
8.5 |
40 |
55 |
|
16.40-Q-10/Z15 |
10 |
12.5 |
12.5 |
45 |
2 |
2 |
15 |
40 |
55 |
|
16.40-Q-10/Z20 |
10 |
12.5 |
12.5 |
45 |
2 |
2 |
20 |
40 |
55 |
|
|
|
|
|
|
|
|
|
|
|
|
16.50-Q-10/Z8.5 |
10 |
12.5 |
12.5 |
45 |
2 |
2.5 |
8.5 |
50 |
65 |
|
16.50-Q-10/Z15 |
10 |
12.5 |
12.5 |
45 |
2 |
2.5 |
15 |
50 |
65 |
|
16.50-Q-10/Z20 |
10 |
12.5 |
12.5 |
45 |
2 |
2.5 |
20 |
50 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
16.100-Q-10/Z8.5 |
10 |
12.5 |
12.5 |
45 |
2 |
5 |
8.5 |
100 |
115 |
|
16.100-Q-10/Z15 |
10 |
12.5 |
12.5 |
45 |
2 |
5 |
15 |
100 |
115 |
|
16.100-Q-10/Z20 |
10 |
12.5 |
12.5 |
45 |
2 |
5 |
20 |
100 |
115 |
|
|
|
|
|
|
|
|
|
|
|
|
16.160-Q-10/Z8.5 |
10 |
12.5 |
12.5 |
45 |
2 |
8 |
8.5 |
160 |
175 |
|
16.160-Q-10/Z15 |
10 |
12.5 |
12.5 |
45 |
2 |
8 |
15 |
160 |
175 |
|
16.160-Q-10/Z20 |
10 |
12.5 |
12.5 |
45 |
2 |
8 |
20 |
160 |
175 |