Special Offer!  Systems for Reflectance, Absorbance and Fluorescence measurements are now 10% off

Flame UV-VIS Absorbance Spectrophotometer

200-850nm spectrophotometer for 1cm cuvettes

FLAME-ABS-BUNDLE
UV-VIS absorbance Flame spectrophotometer system, ready to go — Spectrecology

Our Flame UV-VIS spectrophotometer provides absorbance spectra from 200 – 850nm for standard 1cm cuvettes. The FLame is our newest and most thermally stable spectrometer yet. The flame also boasts user interchangeable slits, fast data acquisition (spectra every 1 msec) and it couples to our 2500+ fiber optic accessories.

The system includes our new DH-mini deuterium-tungsten light source, fibers cuvette holder, software and cuvettes. As an added bonus, Spectrecology also includes 2 fine quartz cuvettes and a cuvette rack.

 

SE-FLAME-ABS is a $7248 value, with a special price of just $6524

Buy a SE-FLAME-ABS system online!

 

FLAME-S-UV-VIS FLAME-S-UV-VIS Spectrometer Assembly 1 $3,384.00 $3,384.00
INTSMA-KIT KIT of Interchangeable Round SMA  connectors; 5um; 10um; 25um; 50um; 100um and 200um 1 $499.00 $499.00
OCEANVIEW OceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server) 1 $214.00 $214.00
CUV-UV Cuvette Holder, 1-cm path, 200-2000 nm 1 $495.00 $495.00
1-Q-10
Standard Rectangular Quartz Cell, 10mm
2 81.37 162.74
SE-111168
Cuvette rack, 12 position, polyethylene
1 15.00 15.00
DH-MINI High Power MINI Deuterium Tungsten Halogen Source w/shutter 200-2000nm 1 $2,397.00 $2,397.00
QP400-025-SR-BX 400 um Premium Fiber, solarization-resistant, 25 cm, BX Jacket 2 $148.00 $296.00
1-Q-10 Standard Rectangular Quartz Cell, 10mm 2 $79.00 $158.00
*** TOTAL $7,248.74
Promotional Discount (10%) -$724.87
Your Price $6.523.97

 

Kit includes 2 Suprasil high quality fully fused cuvettes and a cuvette rack

 

Specifications FLAME-S  
SPECTROSCOPIC
Optical resolution: 1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio: 250:1 (full signal)
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds
Stray light: <0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array
Detector range: 200 – 850 nm
Pixels: 2048
PHYSICAL
Dimensions: 88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g
Engineering Specifications
DH-mini
Sources: Deuterium & Tungsten Halogen
Wavelength range: 200-2500 nm
Color temperature: unknown
Nominal bulb power: ~7 W (deuterium); ~2 W (tungsten halogen)
Typical output power:* 19 µW (deuterium bulb)
14 µW (tungsten bulb)
Warm-up time:** 6 minutes
Source lifetime: 1,000 hours
Stability of optical output: <0.1%
Drift of optical output: <0.2% per hour
Trigger/shutter input signal: TTL; up to 2.5 Hz maximum
Trigger/shutter connection: 4 pin galvanically isolated TTL connector (SUB-D-15 adapter cable provided)
Integrated filter holder: No
Operating temperature: 5 °C – 35 °C
Operating humidity: 5-95% without condensation at 40 °C
Power requirements: 12 VDC
Power consumption: up to 15 W
Dimensions: 7.5 cm x 8.2 cm x 17.5 cm
Weight: 0.5 kg
Safety & regulatory: CE; ROHS; WEEE
Replacement bulb: DH-MINI-B

* Typical output power coupled into a 600 μm UV-Vis fiber and measured with an optical power meter integrated from 200-1100 nm

**  Warm-up time @23 °C ambient, free airflow, no vibrations

 

Flame VIS Fluorescence Spectrophotometer

350-1000nm emission spectrometer, LED excitation, 1cm cuvettes

 

SE-BUNDLE-FL
Flame Fluorescence System, 365nm excitation, cuvette holder and Flame spectrometer – Spectrecology

Our FLAME fluorescence system provides fluorescence emission spectra from 350-1000nm. Excitation is from a high power fiber coupled  LED. The kit comes with a 365nm LED and as an added bonus Spectrecology also includes a 470nm LED that can be switched by the user. The cuvette holder features 4 ports for fluorescence or absorbance measurements, mirror inserts to enhance excitation and emission collection efficiency and a quartz fluorescence cuvette. Spectrecology also includes a pack of 100 4 sided disposable cuvettes.

 

 

SE-FLAME-FL is a $6,860 value, with a special price of just $6,174

Buy a SE-FLAME-FL online!

 

FLAME-S-VIS-NIR-ES FLAME-S-VIS-NIR-ES Spectrometer Assembly 1 $3,435.00 $3,435.00
INTSMA-KIT KIT of Interchangeable Round SMA  connectors; 5um; 10um; 25um; 50um; 100um and 200um 1 $499.00 $499.00
OCEANVIEW OceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server) 1 $214.00 $214.00
CUV-ALL-UV Cuvette Holder, 4 collimators, 1-cm path, 200-2000 nm 1 $1,002.00 $1,002.00
CUV-COVER CUV-UV Tall Cuvette Cover 1 $33.00 $33.00
LLS-365 High-Power LED Light Source, 365nm, SMA Connector 1 $911.00 $911.00
MLA-LED-470 High-Power LED Module, 470nm, includes pre-programmed EEPROM, heatsink, and SMA connector 1 $291.00 $291.00
3-Q-10 Rectangular fluorometer cell, Spectrosil, 10mm 1 $149.35 $149.35
SE-202295 Cuvette, 4 clear sides for fluorescence, macro, VIS  100/pK 1 $29.95 $29.95
QP600-025-UV-BX 600 um Premium Fiber, UV/VIS, 25 cm 2 $148.00 $296.00
SE-111168 Cuvette Rack 12 position 1 $15.00 $15.00
TOTAL $6,860.30
Promotional Discount (10%) -$686.03
Your Price $6,124.27
Specifications FLAME-S-VIS-NIR-ES  
SPECTROSCOPIC
Optical resolution: 1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio: 250:1 (full signal)
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds
Stray light: <0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array
Detector range: 350 – 1000 nm
Pixels: 2048
PHYSICAL
Dimensions: 88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g
Number CWL FWHM  Min Power coupled into a 600 um .22NA fiber  Maximum Drive Current (Continuous Mode) Maximum Drive Current (Pulsed Mode)  Maximum Duty Cycle (Pulsed Mode) 
LLS-365  365 nm 9 nm 1 mW 500 mA 1000 mA 50%
LLS-470  470  nm 25 nm 1 mW 1500 mA 3000 mA 50%

Flame VIS-NIR Reflectance

350-1000nm reflectance spectrophotometer fiber optic

 

FLAME-BUNDLE-REFLECTANCE
Flame spectrometer with classic fiber optic reflection probe, holder and white standard – Spectrecology

Our FLAME reflection system uses a classic 6 around 1 reflection probe. This was the very first fiber probe developed by Ocean Optics nearly 20 years ago, and it has been used extensively for measuring reflectance for color determination, thin film thickness measurement, reflectance of optics, backscattering in tissue and fluids and even fluorescence. The system includes a light source, reflection probe, white standard, software and holder and of course the VIS-NIR Flame spectrometer.

 

SE-FLAME-VIS REFLECTANCE is a $6817 value, with a special price of just $6135

Buy a SE-FLAME-REFLECTANCE system online!
FLAME-S-VIS-NIR-ES FLAME-S-VIS-NIR-ES Spectrometer Assembly 1 $3,435.00 $3,435.00
OCEANVIEW OceanView spectroscopy software with graphical user interface; 1 license (2 installations, accessible by download only from our secure server) 1 $214.00 $214.00
INTSMA-KIT KIT of Interchangeable Round SMA  connectors; 5um; 10um; 25um; 50um; 100um and 200um 1 $499.00 $499.00
HL-2000-HP-FHSA HL-2000-FHSA with 20W output 1 $1,631.00 $1,631.00
R400-7-VIS-NIR 400 um Reflection Probe, VIS/NIR, 2 m 1 $619.00 $619.00
RPH-1 Reflection Probe Holder for 6.35-mm diameter probes 1 $113.00 $113.00
WS-1 Diffuse Reflectance Standard, PTFE 1 $306.00 $306.00
TOTAL $6,817.00
Promotional Discount (10%) -$681.70
Your Price $6,135.30
Specifications FLAME-S-VIS-NIR-ES  
SPECTROSCOPIC
Optical resolution: 1.5 nm FWHM  with 25 micron slit, kit includes 5,10,25,50,100 and 200 um slits that usr can change
Signal-to-noise ratio: 250:1 (full signal)
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds
Stray light: <0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array
Detector range: 350 – 1000 nm
Pixels: 2048
PHYSICAL
Dimensions: 88.9 mm x 63.5 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g
Engineering Specifications HL-2000 Series
Source: Tungsten Halogen
Wavelength range: 360-2400 nm
Color temperature: 2,960 K
Nominal bulb power: 5 W
Typical output power: See chart below
Warm-up time:* 10 minutes
Source lifetime: 1,500 hours (typical)
Stability of optical output: 0.15% peak-to-peak
Drift of optical output: <0.3% per hour
Trigger/shutter: HL-2000-FHSA only
Integrated filter holder & attenuator: HL-2000-FHSA only
Operating temperature: 5 °C – 35 °C
Operating humidity: 5-95% without condensation at 40 °C
Power requirements: 12 VDC
Power consumption: up to 15 W
Dimensions: 6.2 cm x 6 cm x 15 cm
Weight: 0.5 kg
Safety & regulatory: CE; ROHS, WEEE
Replacement bulb: HL-2000-B
*  Warm-up time @23 °C ambient, free airflow, no vibrations
Engineering Specifications HL-2000-HP Family
Source: High-powered Tungsten Halogen
Wavelength Range: 360-2400 nm
Color temperature: 3,000 K
Nominal bulb power: 20 W
Typical output power: See chart below
Warm-up time:* 10 minutes
Source lifetime: 1,000 hours (typical)
Stability of optical output: 0.25% peak-to-peak
Drift of optical output: <0.3% per hour
Trigger/shutter input signal: TTL; Up to 2.5 Hz maximum
Trigger/shutter connection: SUB-D-15 pin
Integrated filter holder: HL-2000-HP-FHSA only
Operating temperature: 5 °C – 35 °C
Operating humidity: 5-95% without condensation at 40 °C
Power requirements: 24 VDC
Power consumption: up to 30 W
Dimensions: 6.2 x 6 x 15 cm
Weight: 0.5 kg
Safety & regulatory: CE; ROHS, WEEE
Replacement bulb: HL-2000-HP-B
*  Warm-up time @23 °C ambient, free airflow, no vibrations
Output Power
The table below reports typical output power coupled into a 600 μm UV/VIS fiber and measured with an optical power meter integrated from 200-1100 nm.
Model Output
HL-2000-HP-FHSA 8.4 mW
Shutter/Trigger Options
Available only for the listed models
Engineering Specifications HL-2000-HP-FHSA
Trigger/shutter input signal: TTL; Up to 2.5 Hz maximum
Trigger/shutter connection: SUB-D-15 pin

FLAME VIS-SWIR Reflectance

350 – 1650nm reflectance spectrophotometer

Low cost NIR reflection spectrometer - Spectrecology

New! Low cost FLAME SWIR spectrometer covers 950-1650nm coupled with a FLAME VIS-NIR unit covering 350-1000nm.  Combined unit provides reflectance values from 350-1650nm.

Unique integrated light source and diffuse reflection probe couples to a bifurcated fiber to bring reflected light back to the 2 spectrometers. The probe has a built in white reflectance standard.

The un-cooled InGaAs array detector provides excellent signal to noise for SWIR wavelengths at a very low cost.

  • Moisture measurement
  • Measure grain and feed quality
  • Measure composition of fats and oils
  • Pharmaceutical ingredients blending
  • Plants, soils, natural products
  • Melamine
FLame VIS-NIR-SWIR Reflectance system is a $12,707 value, now just $11,436
Buy a Flame VIS-SWIR Reflectance System Online

 

FLAME-NIR-INTSMA25 $7,000.00
Flame-S-VIS-NIR-ES $3,435.00
Oceanview $214.00
TC-DR-PROBE $1,600.00
QBIF600-VIS-NIR $458.00
 Total $12,707.00
Discount (10%) -$1,270.70
 Your Price $11,436.30

Optical Specifications of the 2 spectrometers

Specifications FLAME-NIR
SPECTROSCOPIC
Wavelength range: 950-1650 nm (standard preconfigured)
Optical resolution: ~10 nm FWHM (configuration dependent)
Signal-to-noise ratio: 6000:1 (full signal)
Dynamic Range 6000:1
Integration time: 1 ms → 65 seconds
DETECTOR
Detector: Hamamatsu G8160-03
Detector response: 900-1700 nm
Pixels: 128
PHYSICAL
Dimensions: 89.1 mm x 63.3 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g

 

FLAME-NIR BUNDLE – Ocean Optics

 Specifications FLAME-S FLAME-T
SPECTROSCOPIC
Optical resolution: ~0.1-10.0 nm FWHM (configuration dependent)
Signal-to-noise ratio: 250:1 (full signal) 300:1 (at full signal)
Dark noise: 50 RMS counts
Dynamic range: 1300:1 for a single acquisition, 8.5 x 10^7 (system)
Integration time: 1 ms – 65 seconds  3.8 ms – 10 seconds
Corrected linearity: >99%
ELECTRONICS
A/D resolution: 16 bit
Power consumption: 250 mA @ 5 VDC
Inputs/Outputs: 8 x  user programmable GPIOs
Trigger modes: 4 modes
Strobe functions: Yes
Gated delay feature: Yes
Connectors: USB, high density 40 pin JAE DD4 connector
DETECTOR
Detector: Sony ILX511B linear silicon CCD array Toshiba TCD1304AP linear silicon CCD array
Detector range: 190-1100 nm 190-1100 nm
Pixels: 2048 3648
PHYSICAL
Dimensions: 89.1 mm x 63.3 mm x 31.9 mm (34.4 mm with feet)
Weight: 265 g
Diffuse Reflectance Probe

Specifications TC-DR-Probe
Probe type: Diffuse reflectance with integrated light source
Fiber connector: SMA 905
Fiber diameter/type: Works with any standard Ocean Optics fiber diameter and type
Probe material: Anodized Al
PROBE OPTICS
Probe geometry (collection optics): 45° (fixed illumination angle)
Focal length: 40 mm standard (custom options available); 40 mm standoff block included
Effective illumination spot size: ~15 mm
Effective collection (reading) spot size: ~12 mm
Reflectance standard: Spectralon
Block accessory: For use in dark measurements
INTEGRATED LIGHT SOURCE
Light source: 6W tungsten halogen
Bulb lifetime: 10,000 hours
Power supply: Wall plug – 110/240 AC input; 5 VDC output
APPLICATIONS and TECHNIQUES TIPS
Targeted techniques: Diffuse Vis-NIR reflectance of solid samples with rough or matte surfaces
Best for: Color measurement, materials identification and reflectance of food, feed and crops
Referencing: Spectralon reflectance standard included
Companion accessory: Use with DynaCup rotating sample holder for diffuse reflectance of irregularly shaped samples such as grains
Also recommended: Add an adjustable fixture or clamp for mounting the probe above samples; options include Ocean Optics probe holder accessories

 

VIS-NIR-SWIR Reflection system - Spectrecology